Multi Splits Series
HKD Indoor Units
HND Indoor Units
CBD Indoor Units
XAD Indoor Units
DCD Indoor Units
Outdoor Units
AWSI-HKD009-N11
AWSI-HND009-N11
AWAU-YCZ218-H11
AWSI-HKD012-N11
AWSI-HND012-N11
AWSI-CBD012-N11
AWSI-XAD012-N11
AWSI-DCD012-N11
AWAU-YCZ327-H11
AWSI-HKD018-N11
AWSI-HND018-N11
AWAU-YCZ430-H11
AWAU-YCZ536-H11
REFRIGERANT
REFRIGERANT
R410A
HEATPUMP
REFRIGERANT
SM YCZ DCI 1-A.1 GB
AUG 2014
Zobrazit stránku 0
1 2 3 4 5 6 ... 131 132

Shrnutí obsahu

Strany 1 - Multi Splits Series

Multi Splits Series HK

Strany 2 - Contents i

Product specification 8 General Information Model Indoor Unit AWSI-HND009-N11 AWSI-HND012-N11 Installation Method of Pipe Flared Flared Charact

Strany 3 - General Information

Electrical Control Function 98 Electrical Control System 38 EXV open angle for B indoor unit If the value is higher than 99, the digital display tu

Strany 4 - 1. Model Lists

Electrical Control Function Electrical Control System 99 T1 Ts40a31-13120bcdef2 Capacity area a b c d e f Norm value (N) 3 2 1.5 1 0.5 0 1.3.12.4

Strany 5 - 2. External Appearance

Troubleshooting 100 Electrical Control System 2. Troubleshooting 2.1 Display board 2.1.1 Icon explanation on indoor display board (HKD& HND).

Strany 6 - 3. Product specification

Troubleshooting Electrical Control System 101 2.1.3 Icon explanation on indoor display board (Compact cassette). 2.1.4 Icon explanat

Strany 7

Troubleshooting 102 Electrical Control System 2.2 Indoor unit malfunction For HKD,HND Display Operation lamp flash times Timer lamp F

Strany 8

Troubleshooting Electrical Control System 103 For Console: NO. Malfunction Running lamp Timer lamp Defrosting lamp 1 Open or short circuit of T1 te

Strany 9

Troubleshooting 104 Electrical Control System 2.3 Outdoor unit malfunction Display LED STATUS E0 Outdoor EEPROM malfunction E2 Indoor / outdoor uni

Strany 10

Troubleshooting Electrical Control System 105 2.4 Solving steps for typical malfunction 2.4.1 For the indoor unit 2.4.1.1 Indoor EEPROM malfunction

Strany 11

Troubleshooting 106 Electrical Control System 2.4.1.2 Indoor / outdoor units communication error Indoor / outdoor units communication errorStart

Strany 12

Troubleshooting Electrical Control System 107 Pic 2: :IPM (For dual/tri-zone) Self-Check Power, Operating Self-Check

Strany 13 - Indoor Units

Product specification General Information 9 Model Indoor Unit AWSI-HKD012-N11 AWSI-HKD018-N11 Installation Method of Pipe Flared Flared Characteri

Strany 14 - HKD Type

Troubleshooting 108 Electrical Control System . PIC3 :Main board LED when power on and unit standby. PIC 4: check point button, Press 1 t

Strany 15 - 1. Function

Troubleshooting Electrical Control System 109 2.4.1.3 indoor unit fan speed has been out of control Shut off the power supply and turn it on 1 mi

Strany 16 - 2. Dimensions

Troubleshooting 110 Electrical Control System For console: 546321 NO. Color 1 Red 2 --- 3 White 4 Blue 5 Yellow 6 Black For oth

Strany 17 - 3. Wiring Diagrams

Troubleshooting Electrical Control System 111 For console: 546321 DC motor voltage input and output For HKD &HND: NO. Color Signal Voltage 1

Strany 18 - 16 Indoor Units

Troubleshooting 112 Electrical Control System 2.4.1.4 Open or short circuit of temperature sensor. Check the connections between temperature sen

Strany 19

Troubleshooting Electrical Control System 113 2.4.2 For the outdoor unit 2.4.2 1 Outdoor EEPROM malfunction(ODU E0) If the EEPROM chip is welded o

Strany 20 - 18 Indoor Units

Troubleshooting 114 Electrical Control System 2.4.2.2 Communication malfunction between IPM board and outdoor main board(ODU E3) Communication m

Strany 21

Troubleshooting Electrical Control System 115 2.4.2.3 Voltage protection(ODU E5) Voltage protection Check the voltage of outdoor unit power suppl

Strany 22 - 20 Indoor Units

Troubleshooting 116 Electrical Control System 2.4.2.4 Outdoor unit fan speed has been out of control (E8) Shut off the power supply and turn it

Strany 23

Troubleshooting Electrical Control System 117 Index 1: 1.Outdoor DC fan motor(control chip is inside fan motor) Measure the resistance value of eac

Strany 24 - HND Type

Product specification 10 General Information Model Indoor Unit AWSI-CBD012-N11 Installation Method of Pipe Flared Characteristics Units Cooli

Strany 25

Troubleshooting 118 Electrical Control System 2.4.2.5 High pressure protection (ODU P1) (For AWAU-YCZ430-H11, AWAU-YCZ536-H11) High pressure pro

Strany 26

Troubleshooting Electrical Control System 119 2.4.2.6 Low pressure protection (ODU P2) (For AWAU-YCZ430-H11, AWAU-YCZ536-H11) Low pressure protect

Strany 27 - AWSI-HND012-N11

Troubleshooting 120 Electrical Control System 2.4.2.7 Current protection of compressor(ODU P3) Current protection of compressorJudge 1: Check wh

Strany 28

Troubleshooting Electrical Control System 121 2.4.2.8 Temperature protection of compressor discharge(ODU P4) Temperature protection of compressor d

Strany 29 - Indoor Units 27

Troubleshooting 122 Electrical Control System 2.4.2.9 High temperature protection of condenser(ODU P5) When outdoor pipe temperature is more tha

Strany 30

Troubleshooting Electrical Control System 123 2.4.2.10 IPM module protection(ODU P6) IPM module protectionCheck whether the voltage range of P-

Strany 31 - Indoor Units 29

Troubleshooting 124 Electrical Control System 2.4.3 Main parts check Spec. Indoor unit Model AWSI-HND009-N11 AWSI-HND012-N11 AWSI-HND018-N11 Ind

Strany 32

Troubleshooting Electrical Control System 125 1. Temperature sensor checking Disconnect the temperature sensor from PCB, measure the resistance v

Strany 33 - Indoor Units 31

Troubleshooting 126 Electrical Control System Appendix 1 Temperature Sensor Resistance Value Table for T1,T2,T3,T4,T2B (℃--K) ℃ K Ohm ℃ K Ohm ℃

Strany 34

Troubleshooting Electrical Control System 127 Appendix 2 Temperature Sensor Resistance Value Table for T5 (℃--K) ℃ K Ohm ℃ K Ohm ℃ K Ohm ℃ K Ohm -

Strany 35 - Light Commercial

Indoor Units Indoor Units 11 Part 2 Indoor Units HKD Type ... 12 HND Typ

Strany 36 - 1. Features

Troubleshooting 128 Electrical Control System 2.Compressor checking Measure the resistance value of each winding by using the tester. Positi

Strany 37 - Light Commercial 35

Troubleshooting Electrical Control System 129 3. IPM continuity check Turn off the power, let the large capacity electrolytic capacitors discharge

Strany 38 - 1.2 A5 Duct

SERVICE MANUAL Multi Splits Series

Strany 39 - Light Commercial 37

HKD Type 12 Indoor Units HKD Type 1. Function ... 13 2. Dimensions .

Strany 40 - ⑺ Built-in display board

Function Indoor Units 13 1. Function Killer Of FormaldehydeSilver Ico Filter(O)Vitamin C Filter(O)3M HAM Filter(O)Bio Filter(O)Golden Fin(O)Ionizer

Strany 41 - 1.3 Console

Dimensions 14 Indoor Units 2. Dimensions WDH Model L(mm) R(mm) H(mm) Dimension of installation hole(mm) AWSI-HKD009-N11 100 95 45 ¢65 A

Strany 42

Wiring Diagrams Indoor Units 15 3. Wiring Diagrams AWSI-HKD009-N11, AWSI-HKD012-N11, AWSI-HKD018-N11

Strany 43 - 2.3 Console

Exploded View and Spare Part list 16 Indoor Units 4. Exploded View and Spare Part list Exploded View of indoor unit: AWSI-HKD009-N11

Strany 44 - 3. Service Space(unit:mm)

Exploded View and Spare Part list Indoor Units 17 Spare part list of indoor unit: AWSI-HKD009-N11 No. Part Name Qty BOM Code No. Part Name

Strany 45 - 3.3 Console

Contents Contents i Part 1 General Information ...

Strany 46 - 4. Wiring Diagrams

Exploded View and Spare Part list 18 Indoor Units Exploded View of indoor unit: AWSI-HKD012-N11

Strany 47 - AWSI-DCD012-N11

Exploded View and Spare Part list Indoor Units 19 Spare part list of indoor unit: AWSI-HKD012-N11 No. Part Name Qty BOM Code No. Pa

Strany 48 - AWSI-XAD012-N11

Exploded View and Spare Part list 20 Indoor Units Exploded View of indoor unit: AWSI-HKD018-N11

Strany 49 - Light Commercial 47

Exploded View and Spare Part list Indoor Units 21 Spare part list of indoor unit: AWSI-HKD018-N11 No. Part Name Qty BOM Code No. Part

Strany 50

HND Type 22 Indoor Units HND Type 1. Function ... 23 2. Dimensions ...

Strany 51 - Light Commercial 49

Function Indoor Units 23 1. Function Cold catalyst filterPlasma(O)Silver Ico Filter(O)Vitamin C Filter(O)3M HAM Filter(O)Bio Filter(O)Golden Fin(O)

Strany 52

Dimensions 24 Indoor Units 2. Dimensions W D Model W D H AWSI-HND009-N11 750 198 280 AWSI-HND012-N11 835 198 280 AWSI-HND018-N11 990 218 3

Strany 53 - Light Commercial 51

Dimensions Indoor Units 25 Model L(mm) R(mm) H(mm) Dimension of installation hole(mm) AWSI-HND009-N11 180 110 45 ¢65 AWSI-HND012-N11 140 110 45

Strany 54

Wiring Diagrams 26 Indoor Units 3. Wiring Diagrams AWSI-HND009-N11, AWSI-HND012-N11 AWSI-HND018-N11

Strany 55 - Outdoor Units

Exploded View and Spare Part list Indoor Units 27 4. Exploded View and Spare Part list Exploded View of indoor unit: AWSI-HND009-N11

Strany 56 - 1. Dimensions

General Information General Information 1 Part 1 General Information 1. Model Lists ...

Strany 57 - AWAU-YCZ327-H11

Exploded View and Spare Part list 28 Indoor Units Spare part list of indoor unit: AWSI-HND009-N11 No. Part Name Qty BOM Code No. Part N

Strany 58 - AWAU-YCZ430-H11

Exploded View and Spare Part list Indoor Units 29 Exploded View of indoor unit: AWSI-HND012-N11

Strany 59 - AWAU-YCZ536-H11

Exploded View and Spare Part list 30 Indoor Units Spare part list of indoor unit: AWSI-HND012-N11 No. Part Name Qty BOM Code No.

Strany 60 - 2. Service Space

Exploded View and Spare Part list Indoor Units 31 Exploded View of indoor unit: AWSI-HND018-N11

Strany 61 - Outdoor Units 59

Exploded View and Spare Part list 32 Indoor Units Spare part list of indoor unit: AWSI-HND018-N11 No. Part Name Qty BOM Code No. P

Strany 62 - 60 Outdoor Units

Light Commercial Indoor Units 33 Light Commercial 1. Features ... 34 2. D

Strany 63 - 4. Wiring Diagrams

Features 34 Indoor Units 1. Features 1.1 Four-way cassette type(compact) ⑴ New panel  360°surrounding air outlet design, affords comfortab

Strany 64

Features Light Commercial 35 ⑸ Air passage function  Reserves the space for air outlet from the side of indoor unit; It’s availed

Strany 65 - 5. Indoor units combination

Features 36 Indoor Units 1.2 A5 Duct ⑴ Installation accessories: (Optional)  Front Board, Canvas Air Passage, Filter, Panel, for easy installa

Strany 66 - 6. Operation Limits

Features Light Commercial 37  Replace the motor or centrifugal fan Remove the ventilated panel firstly. Remove a half of blower housing and take

Strany 67 - 7. Sound Levels

Model Lists 2 General Information 1. Model Lists 1.1 Indoor Units Cooling & Heating Indoor units type Indoor units model Capacity(Btu/h) Pow

Strany 68 - 66 Outdoor Units

Features 38 Indoor Units ⑺ Built-in display board  The standard indoor unit can be controlled by wired controller.  There is a display

Strany 69

Features Light Commercial 39 1.3 Console (1) Consumes up to 30% less energy than non-inverter units ——DC inverter compressor ——indoor fan motor ad

Strany 70 - 68 Outdoor Units

Dimensions 40 Indoor Units 2. Dimensions 2.1 Four-way cassette type(compact): 2.2 A5 Duct HGEFABDC LM

Strany 71

Dimensions Light Commercial 41 Model Outline dimension(mm) Air outlet opening size Air return opening size Size of outline dimension mounted plug

Strany 72 - 70 Outdoor Units

Service Space(unit:mm) 42 Indoor Units 3. Service Space(unit:mm) 3.1 Four-way cassette(compact) 3.2 A5 Duct Ensure enough space required fo

Strany 73

Service Space(unit:mm) Light Commercial 43 3.3 Console

Strany 74 - 72 Outdoor Units

Wiring Diagrams 44 Indoor Units 4. Wiring Diagrams AWSI-CBD012-N11 AWSI-DCD012-N11

Strany 75

Wiring Diagrams Light Commercial 45 AWSI-DCD012-N11

Strany 76 - Installation

Wiring Diagrams 46 Indoor Units AWSI-XAD012-N11

Strany 77 - 2. Connecting the cables

Exploded View and Spare Part list Light Commercial 47 5. Exploded View and Spare Part list Exploded View of indoor unit:AWSI-CBD012-N11

Strany 78 - 76 Installation

External Appearance General Information 3 2. External Appearance 2.1 Indoor Units HKD HND Four-way cassette(Compact) Duct Console 2.2 Outd

Strany 79

Exploded View and Spare Part list 48 Indoor Units Spare part list of indoor unit:AWSI-CBD012-N11 No. Part Name Qty BOM Code No. Part Na

Strany 80 - 78 Installation

Exploded View and Spare Part list Light Commercial 49 Exploded View of indoor unit: AWSI-DCD012-N11

Strany 81 - Installation 79

Exploded View and Spare Part list 50 Indoor Units Spare part list of indoor unit: AWSI-DCD012-N11 No. Part Name Qty BOM Code No. Part Nam

Strany 82 - 80 Installation

Exploded View and Spare Part list Light Commercial 51 Exploded View of indoor unit:AWSI-XAD012-N11

Strany 83 - Installation 81

Exploded View and Spare Part list 52 Indoor Units Spare part list of indoor unit:AWSI-XAD012-N11 No. Part Name Qty BOM Code No. Part Na

Strany 84 - 82 Installation

Outdoor Units Outdoor Units 53 Part 3 Outdoor Units 1. Dimensions ... 54 2. Se

Strany 85 - Installation 83

Dimensions 54 Outdoor Units 1. Dimensions AWSI-XAD012-N11 560 W1H6D1 335D2 360845 W313D3335D1R6R5A122A250B1120110B2700W273585858110H1H2200.

Strany 86 - 7.2. Refrigerant charging

Dimensions Outdoor Units 55 AWAU-YCZ327-H11 900 W590 W1860H12D2 355D1 333302D3333D1

Strany 87 - Electrical Control System

Dimensions 56 Outdoor Units AWAU-YCZ430-H11 900 W590 W1860H12D2 355D1 333302D3333D1509790B2B18A25555 55 55 55 55 5511062W2H1H2R6238.4285.7L1

Strany 88 - 1.2 Main Protection

Dimensions Outdoor Units 57 AWAU-YCZ536-H11

Strany 89

Product specification 4 General Information 3. Product specification Model Outdoor Unit AWAU-YCZ218-H11 Installation Method of Pipe 2 x AWSI-HND

Strany 90 - T4LimFre5_ADD

Service Space 58 Outdoor Units 2. Service Space More than 60cmMore than 30cmMore than 60cmMore than 200cmAir inletAir inletMore than 30cmAir ou

Strany 91

Refrigeration Cycle Diagram Outdoor Units 59 3. Refrigeration Cycle Diagram 3.1 Refr

Strany 92

Refrigeration Cycle Diagram 60 Outdoor Units LIQUID VALVE AGAS VALVE AHEATEXCHANGE(EVAPORATOR)HEATEXCHANGE(CONDENSER)Compressor4-WAY VALVECOOLI

Strany 93

Wiring Diagrams Outdoor Units 61 4. Wiring Diagrams AWAU-YCZ218-H11 AWAU-YCZ327-H11

Strany 94 - T1-Ts-ΔT

Wiring Diagrams 62 Outdoor Units AWAU-YCZ430-H11 AWAU-YCZ536-H11

Strany 95

Indoor units combination Outdoor Units 63 5. Indoor units combination 5.1 Indoor uni

Strany 96

Operation Limits 64 Outdoor Units 6. Operation Limits Temperature Mode Cooling operation

Strany 97

Sound Levels Outdoor Units 65 7. Sound Levels H1.0mOutdoor UnitMicrophone Note: H= 0.

Strany 98

Exploded View and Spare Part list 66 Outdoor Units 8. Exploded View and Spare Part list Exploded View of outdoor unit: AWAU-YCZ218-H11

Strany 99

Exploded View and Spare Part list Outdoor Units 67 Spare part list of outdoor unit:

Strany 100

Product specification General Information 5 Model Outdoor Unit AWAU-YCZ327-H11 Installation Method of Pipe 3 x AWSI-HND009-N11 3 x AWSI-HKD009-N11

Strany 101

Exploded View and Spare Part list 68 Outdoor Units Exploded View of outdoor unit: AWAU-YCZ327-H11

Strany 102 - 2. Troubleshooting

Exploded View and Spare Part list Outdoor Units 69 Spare part list of outdoor unit:

Strany 103 - Troubleshooting

Exploded View and Spare Part list 70 Outdoor Units Exploded View of outdoor unit: AWAU-YCZ430-H11

Strany 104

Exploded View and Spare Part list Outdoor Units 71 Spare part list of outdoor uni

Strany 105 - For Console:

Exploded View and Spare Part list 72 Outdoor Units Exploded View of outdoor unit: AWAU-YCZ536-H11

Strany 106 - 2.3 Outdoor unit malfunction

Exploded View and Spare Part list Outdoor Units 73 Spare part list of outdoor unit:

Strany 107 - 2.4.1 For the indoor unit

Installation 74 Installation Part 4 Installation 1.Wrench torque sheet for installation ... 75

Strany 108 - Troubleshooting

Wrench torque sheet for installation Installation 75 1. Wrench torque sheet for installation Outside diameter Torque Additional tightening torque

Strany 109

Pipe length and the elevation 76 Installation

Strany 110

Installation for the first time Installation 77 4. Installation for the first time Air and moisture in the refrigerant system have undesirable eff

Strany 111

Product specification 6 General Information Model Outdoor Unit AWAU-YCZ430-H11 Installation Method of Pipe 4 x AWSI-HND009-N11 4 x AWSI-HKD009-

Strany 112

Installation for the first time 78 Installation 7) Turn the flare nut of the 3-way valves about 45° counterclockwise for 6 or 7seconds after th

Strany 113 - Cassette:

Installation for the first time Installation 79 7). Mount the valve stems nuts and the service port cap. Be sure to use a torque wrench to tighten

Strany 114

Adding the refrigerant after running the system for many years 80 Installation 5. Adding the refrigerant after running the system for many year

Strany 115 - 2.4.2 For the outdoor unit

Re-installation while the indoor unit need to be repaired Installation 81 6. Re-installation while the indoor unit need to be repaired 6.1. Collec

Strany 116

Re-installation while the indoor unit need to be repaired 82 Installation 6.2. Air purging by the refrigerant Procedure: 1). Confirm that both

Strany 117

Re-installation while the outdoor unit need to be repaired Installation 83 Be sure to check the gas leakage. 7. Re-installation while the outdoor

Strany 118

Re-installation while the outdoor unit need to be repaired 84 Installation 7.2. Refrigerant charging Procedure: 1). Connect the charge hose to

Strany 119

Electrical Control System Electrical Control System 85 Part 5 Electrical Control System 1. Electrical Control Function ...

Strany 120

Electrical Control Function 86 Electrical Control System 1. Electrical Control Function 1.1 Definition T1: Room Air Thermistor (RAT) T2: Ind

Strany 121

Electrical Control Function Electrical Control System 87 COOL_F6 ICOOLLMT2 COOL_F5 ICOOLLMT1 If the current frequency is lower than COOL_F4, the fr

Strany 122

Product specification General Information 7 Model Outdoor Unit AWAU-YCZ536-H11 Installation Method of Pipe 5 x AWSI-HND009-N11 5 x AWSI-HKD009-N11

Strany 123

Electrical Control Function 88 Electrical Control System 3.53.0HighLow1.0Medium1.5 For HKD,HND, Console abcd5.04.02.51.06.0T1-24eH(H-L)*0.75+L(H-L

Strany 124

Electrical Control Function Electrical Control System 89 T4A DC_FAN_HI_SPD_ADDB DC_FAN_MID_SPD_ADDC DC_FAN_MIN_SPD_ADDD DC_FAN_SLOW_SPD_ADDE DC_FAN

Strany 125

Electrical Control Function 90 Electrical Control System The auto fan acts as below rules: abcd5.04.02.51.06.0T1-TseH(H-L)*0.75+L(H-L)*0.5+L(H-L)*

Strany 126 - 2.4.3 Main parts check

Electrical Control Function Electrical Control System 91 T4E DC_FAN_SSLOW_SPD_ADDD DC_FAN_SLOW_SPD_ADDC DC_FAN_MIN_SPD_ADDB DC_FAN_MID_SPD_ADDA DC_

Strany 127

Electrical Control Function 92 Electrical Control System -1.0-2.0-3.0-4.00.0T1-Ts+ΔTL(H+-L)*0.4+L(H+-L)*0.6+L-5.0-6.0-6.5H+(H+-L)*0.8+L(H+-L)*0.6+L

Strany 128

Electrical Control Function Electrical Control System 93 ----T3 rises to be higher than TCDE1℃. ----T3 keeps to be higher than TCDE2℃ for 80 secon

Strany 129

Electrical Control Function 94 Electrical Control System Low indoor room temperature protection All protections are active and the same as that in

Strany 130 - 2.Compressor checking

Electrical Control Function Electrical Control System 95 1.3.10 Forced operation function 1.3.10.1 Enter forced operation function: Press the touch

Strany 131 - 4: Indoor AC Fan Motor

Electrical Control Function 96 Electrical Control System from follow-me signal every 3 minutes. 3) The PCB will take action to the mode ch

Strany 132 - Multi Splits Series

Electrical Control Function Electrical Control System 97 function, it will display No. N with 1.5s, meanwhile the low bit decimal of digit display